{"id":2315,"date":"2024-12-16T13:43:02","date_gmt":"2024-12-16T08:13:02","guid":{"rendered":"http:\/\/new1.sctimst.ac.in\/?page_id=2315"},"modified":"2025-09-19T14:57:06","modified_gmt":"2025-09-19T09:27:06","slug":"central-analytical-facility","status":"publish","type":"page","link":"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/","title":{"rendered":"\u0915\u0947\u0902\u0926\u094d\u0930\u0940\u092f \u0935\u093f\u0936\u094d\u0932\u0947\u0937\u0923\u093e\u0924\u094d\u092e\u0915 \u0938\u0941\u0935\u093f\u0927\u093e"},"content":{"rendered":"\n\n\t<p>The physicochemical characterization of biomaterials is a critical step in understanding their suitability for specific applications, ensuring their safety, and optimizing their performance. This characterization involves the assessment of various physical and chemical properties, which collectively influence their interactions with biological systems. Central Analytical Facility (CAF) offers tests to elucidate the physicochemical properties of materials. Parts 18 and 19 of the ISO 10993 standards of the International Organization for Standardization clearly describe the essential physicochemical characterizations required to evaluate medical devices.<\/p>\n<p>Determining the chemical composition, identification of the elements and functional groups present in the material, assessing the purity, and checking the presence of potential impurities are fundamental in biomaterial characterization. Microstructural analysis provides insights into the material&#8217;s morphology, size, and distribution of its constituent phases. Understanding the mechanical behavior of biomaterials is crucial for applications like orthopedic implants and tissue scaffolds. Tensile, compressive, and shear testing can reveal properties like tensile strength, Young&#8217;s modulus, and toughness. The surface properties of biomaterials such as roughness, wettability, and surface charge significantly impact their interactions with biological environments. For biomaterials intended for temporary use, assessing their degradation rate and degradation products is essential. This involves monitoring changes in mass, size, and chemical composition over time in relevant biological conditions. Biomaterials may be exposed to various environmental conditions. Assessing their chemical stability under conditions such as temperature, pH, and humidity is essential to predict their long-term performance. Thermal analysis can provide information about the material&#8217;s thermal stability and phase transitions. In the context of injectable biomaterials or formulations, rheological measurements help understand their flow behavior, viscosity, and shear-thinning properties.<\/p>\n<p>CAF functions as the nodal center for analyzing the physicochemical properties of materials and devices. CAF hosts an array of state-of-the-art equipment for performing a diverse range of analyses including spectroscopy, thermal, chromatography, mechanical, and imaging. The facility is open for industries and academic institutions to get their analysis done on a payment basis. All the testing activities at CAF are performed under the quality platform following ISO\/IEC 17025. Out of these tests, the following three physicochemical tests are accredited by the National Accreditation Board for Testing and Calibration Laboratories (NABL), India.<\/p>\n<ul>\n<li>Residual ethylene oxide analysis using headspace gas chromatography (HSGC).<\/li>\n<li>Compositional analysis using thermogravimetric analyzer (TGA).<\/li>\n<li>Determination of transition temperatures and enthalpies of fusion and crystallization of materials using differential scanning calorimetry (DSC).<\/li>\n<\/ul>\n<p>Besides testing, CAF organizes technical sessions for the benefit of students, researchers, and teachers. CAF is happy to provide technical advice and guidance to customers on their analytical needs.<\/p>\n<b>For further information on tests and services offered, please contact:<\/b><br \/>\nPhone: \u00a0<b>91-471-2520275\/268\/248<\/b><br \/>\nMail: \u00a0\u00a0\u00a0\u00a0<b>rjoseph@sctimst.ac.in, renjithschem@sctimst.ac.in<\/b>\n<p>&nbsp;<\/p>\n\t<h2 id=\"Facilities\"><strong>Equipment available, their specifications, and tests offered by the Central Analytical Facility are listed below:<\/strong><\/h2>\n<h3><strong>1. Fourier Transform Infrared (FTIR) Spectrometer<\/strong><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png\" alt=\"FTIR\" width=\"216\" height=\"157\" \/><\/p>\n<p>Infrared spectroscopy (IR or vibrational spectroscopy) is a powerful tool for material\u00a0identification. It relies on the interaction of IR radiation with matter. When a material is irradiated with IR radiation, those chemical bonds with definite dipole moments start vibrating, and each vibration will give rise to characteristic peaks. FTIR spectrum will provide information on the functional groups present in the materials. As the fingerprint region of the FTIR spectrum is unique for every molecule, it can be used for the identification and purity analysis of materials.<\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\n<ul>\n<li>Model and manufacturer: Nicolet iS50 (Thermo Fisher Scientific, USA).<\/li>\n<\/ul>\n<h4><strong>Specifications:<\/strong><\/h4>\n<ul>\n<li>Spectral range: 4000 cm<sup>-1<\/sup>\u00a0&#8211; 400 cm<sup>-1<\/sup>.<\/li>\n<li>Resolution: 0.4 cm<sup>-1<\/sup><\/li>\n<li>Modes: Diamond ATR, Transmission mode (KBr), and DRS<\/li>\n<\/ul>\n<p>Nicolet iS50 is equipped with an elaborated database comprising more than 30,000 FTIR spectra of materials such as polymers, organic compounds, plasticizers, additives, common materials, organic solvents, hydrocarbons, and biomolecules. Thus, iS50 is a potential tool for material identification by spectral matching.<\/p>\n<h4><strong>Applications:<\/strong><\/h4>\n<p>FTIR spectroscopic analysis can be used for the identification of materials, especially polymers and organic materials. It can be used for establishing the equivalence of materials with materials already in practice, assessing the purity of materials used for device development, and also for the structural elucidation of unknown materials. It could also be used for monitoring the course of chemical reactions, ensuring the completion of the reactions, and consumption of reactants.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\n<ul>\n<li>FTIR spectroscopic analysis<\/li>\n<\/ul>\n<hr class=\"wm-divider type-dashed\/dotted\/double-line\/line\/whitespace\" style=\"margin-bottom:0px;margin-top:0px\" \/>\n<h3><strong>2. Double beam UV-visible spectrophotometer<\/strong><\/h3>\n<h4><strong>Instrument Details:<\/strong><\/h4>\n<ul>\n<li>Model number and manufacturer: Evolution one plus (Thermo Fisher Scientific, USA)<\/li>\n<\/ul>\n<h4><strong>Specifications:<\/strong><\/h4>\n<ul>\n<li>Wavelength range: 190 to 1100 nm<\/li>\n<li>Double beam<\/li>\n<li>Integrating sphere for powder and film sample analysis <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/UV-Vis1-300x181.png\" alt=\"\" width=\"300\" height=\"181\" \/><\/li>\n<li>Total and Diffuse reflectance measurements<\/li>\n<li>Color analysis<\/li>\n<li>Peltier attachment for temperature-dependent studies<\/li>\n<li>Kinetic measurements<\/li>\n<\/ul>\n<h4><strong>Brief Description:<\/strong><\/h4>\n<p>UV-visible spectrophotometry is one of the most frequently used structural characterization techniques based on Beer-Lambert&#8217;s law. It works on the principle that compounds containing \u03c0-electrons or non-bonding electrons (n-electrons) can absorb the energy in the form of ultraviolet or visible light to excite these electrons to higher anti-bonding molecular orbitals. The wavelength of maximum absorption is inversely proportional to the energy gap between the HOMO and the LUMO of molecules. UV-Vis spectrophotometer can be used for the qualitative analysis (simple read and spectrum scan) as well as quantitative determination of UV\/Vis active analytes such as organic compounds, biological macromolecules, and surface plasmon resonance (SPR) of active nanomaterials.<\/p>\n<h4><strong>Applications:<\/strong><\/h4>\n<p>UV-visible spectroscopic analysis can be used for the structural elucidation of materials. UV-visible spectra could be used to assess the electronic levels and optical band gap of the materials. Loading and release kinetics of drugs to\/from drug delivery systems (DDS) could be monitored by this technique. Transmittance measurement would give the transparency range of optical devices like contact lenses. Reflectance measurement would give the UV reflecting capacity of coatings and paints. Peltier attachment would enable the equipment to study the temperature-dependent variation in the absorbance\/transmittance of thermos-responsive material solutions. Color measurements would help to assess the variation in the color parameters of the material before and after treatment. The surface plasmon resonance (SPR) of nanomaterials could be analyzed using a UV-visible spectrometer. As SPR has a direct relation with the shape and size of nanomaterials, the technique could distinguish nanomaterials based on their aspect ratio. It could also be used for the detection of heavy metal ions from their solutions by colorimetric methods.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\n<ul>\n<li>UV-Visible Absorption analysis (Qualitative)<\/li>\n<li>UV-Visible Absorption analysis (Quantitative)<\/li>\n<\/ul>\n<h3><strong>3. Spectrofluorometer<\/strong><\/h3>\n<p>Spectrofluorometry is an essential structural characterization technique. When compounds containing \u03c0-electrons or nonbonding electrons are excited with radiation with a wavelength corresponding to their absorption maximum, these electrons will migrate to high-energy anti-bonding molecular orbitals. An excited state is highly unstable; hence, the electrons will return to the ground state by emitting absorbed energy in the form of radiation. A spectrofluorometer measures the emitted radiation from an excited molecule and provides information about the compound&#8217;s chemical structure. It can be used for qualitative analysis (simple read and spectrum scan) and quantitative estimation of emissive materials in solutions.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Spectrofluorometer.png\" alt=\"Spectrofluorometer\" width=\"302\" height=\"198\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: FP-8200 (JASCO Inc. Japan)\n<h4><strong>Specifications:<\/strong><\/h4>\nWavelength range: 200 to 800 nm.\n<h4><strong>Applications:<\/strong><\/h4>\n<p>Just like UV-visible spectrometer, a spectrofluorometer could also be used for the structural elucidation of materials. It could be used for studying the enhancement or quenching of emissions in the presence of certain molecules. The emission analysis could be used for detecting the presence of emissive molecules.<\/p>\n<h4><strong>Test offered:<\/strong><\/h4>\nFluorescence spectroscopic analysis (Qualitative)\n<p><strong>4. Analytical Gel Permeation Chromatograph \/ High-Performance Liquid Chromatograph<\/strong><\/p>\n<p>High-performance liquid chromatography (HPLC) is an efficient technique for separating, identifying, and quantifying components in a mixture. It relies on pumps to pass a pressurized liquid solvent (mobile phase) containing the sample mixture through a column filled with a solid adsorbent material (stationary phase). Each component in the sample interacts slightly differently with the adsorbent material, causing different flow rates for the various constituents and separating them as they flow out of the column. UV and RI detectors are used for detecting the components. The time the components take to reach the detector is termed the retention time (TR). Different components in a mixture will have different TR values, based on which they can be identified. Calibration plots connecting the concentration of analytes vs. peak area can be used for their quantification.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Analytical%20Gel.png\" alt=\"Analytical Gel Permeation Chromatograph \/ High Performance Liquid Chromatograph\" width=\"312\" height=\"203\" border=\"0\" \/><\/p>\n<p>Gel permeation chromatographic (GPC) analysis is a vital characterization tool for polymers and macromolecules. GPC separates polymeric molecules based on their size (size exclusion chromatography) when pumped through a column packed with beads composed of cross-linked polymers (styragel or ultrahydrogel). This method can be used for the qualitative purity assay of macromolecular solutions and the estimation of the relative molecular weight and polydispersity index (PDI) of polymers.<\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: Waters 600 (Waters, USA)\n<h4><strong>Specifications:<\/strong><\/h4>\nDetectors: UV (Waters 2487) and RI (Waters 2414).\nHPLC Columns: Normal Phase, C18 &amp; C8.\nGPC Columns: Styragel columns, Ultrahydrogel columns.\n<h4><strong>Applications:<\/strong><\/h4>\n<p>HPLC can be used for the purity analysis of materials, detection, and quantification of specific components (analytes) in mixtures. The analyte matrix of HPLC encompasses a wide range of materials viz. small organic molecules, amino acids, drugs, enzymes, biomolecules, biomarkers, etc. It could be used for the extractable and leachable analysis of polymeric materials specifically for the estimation of residual content of monomers, plasticizers, and solvents. GPC can be used for the analysis of macromolecules of natural or synthetic origin. It would give an idea about their molecular weight distribution and polydispersity index.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nHPLC: Purity assay\/single sample (Qualitative)\nHPLC: Quantification (standards &amp; sample)\nHPLC: Estimation of residual Ethylene glycol (EG) and ethylene chlorohydrin (ECH)\nGPC: Determination of molecular weight of polymers\n<h3><strong>5. High-Performance Liquid Chromatograph with autosampler<\/strong><\/h3>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: LC-2010A HT (Shimadzu, Japan)<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/High-Performance%20Liquid%20Chromatograph%20with%20autosampler.png&quot;\" alt=\"High-Performance Liquid Chromatograph with autosampler \" width=\"167\" height=\"245\" border=\"0\" \/>\n<h4><strong>Specifications:<\/strong><\/h4>\nDetector: UV-visible detector\nHPLC Columns: Normal Phase, C18 &amp; C8.\nAutosampler capable of loading 210 samples\n<h4><strong>Applications:<\/strong><\/h4>\n<p>LC-2010A HT is a high throughput HPLC system capable of analyzing samples in bulk (up to 210). Analytes are detected using a UV-visible detector. This equipment is suitable for method development and quality control analyses.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nHPLC: Purity assay\/single sample (Qualitative)\nHPLC: Quantification (standards &amp; sample)\n<h3><strong>6. Headspace-Gas Chromatograph<\/strong><\/h3>\n<p>Gas chromatography (GC) is used to analyze compounds that can be vaporized without decomposition. GC can be employed to test the purity of volatile substances like organic solvents, separate the components of a mixture (the relative amounts of such components can also be determined), and quantify volatile residues from materials or devices. During GC analysis, the gaseous analytes interact with the column walls coated with a stationary phase and elute at different retention times (TR). Compounds can be identified and quantified by comparing the TR and peak area under specific conditions. Headspace GC analysis is used to analyze highly reactive\/toxic chemicals such as pesticides, sterilizing agents, monomers, etc.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/GC-FID.png\" alt=\"Headspace-Gas Chromatograph (GC-FID)\" width=\"245\" height=\"132\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: Clarus 580 (Perkin Elmer, USA)\n<h4><strong>Specifications:<\/strong><\/h4>\nFlame Ionization Detector\nHeadspace autosampler (Perkin Elmer HS 40)\nPE Elite wax column\n<h4><strong>Applications:<\/strong><\/h4>\n<p>GC-FID can be used for the detection and quantification of organic molecules especially hydrocarbons, solvents, etc. Ethylene Oxide (EtO) has been utilized as a sterilizing agent for biomedical devices owing to its convenient usage. However, the determination of residual EtO is a mandatory post-sterilization analysis due to its toxicity. ISO 10993-7 outlines the methods for estimating residual EtO in sterilized devices and the allowable limits. Headspace gas chromatographic analysis of the extracts of sterilized medical devices and biomaterials will give the idea of residual etO content. The residual content of solvents and monomers in polymeric medical devices could also be analyzed using HS-GC.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nPurity assay\/single sample (Qualitative)\nQuantification (standards &amp; samples)\nEstimation of Residual EtO in EtO sterilized materials\n<h3><strong>7. Differential Scanning Calorimeter<\/strong><\/h3>\n<p>Differential scanning calorimetry, or DSC, measures the heat flow from or to a sample as a function of temperature in comparison with a reference material maintained at an identical temperature. The instrument can monitor thermotropic events such as melting, crystallization, glass transition, curing, sorption, etc. In addition to the precise monitoring of thermal events, it could also deduce thermodynamic properties like enthalpy change and the heat capacity of the materials. Modulated Differential Scanning Calorimetry (mDSC) efficiently monitors even weak thermotropic changes like liquid crystalline phase transitions. The crystallinity, tacticity, and purity of the materials could also be analyzed.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/DSC.png\" alt=\"Differential Scanning Calorimeter (DSC)\" width=\"195\" height=\"199\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModels and manufacturer: Q20 and Q100 (TA Instruments, USA)\n<h4><strong>Specifications:<\/strong><\/h4>\nEquipped with a refrigerated cooling system.\nScan temperature range: -90 to 400 oC (nitrogen atmosphere).\nModulated DSC option for understanding complex thermal curves and to increase the sensitivity of weak transitions.\n<h4><strong>Applications:<\/strong><\/h4>\n<p>DSC is a robust technique to monitor the thermal transitions of materials such as melting, crystallization, glass transition, etc. In addition to the thermal transitions, the thermodynamic parameters associated with the transition (enthalpy of fusion, enthalpy of crystallization, etc.) could also be calculated using DSC. Other information that could be deduced from DSC analysis are heat capacity, crystallinity, tacticity, liquid crystalline phase transitions, denaturing of protein, etc.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nDifferential scanning calorimetry: scan rate 10 \u00baC\/min or above\nDifferential scanning calorimetry: scan rate 5 \u00baC\/min or below\n<h3><strong>8. Simultaneous Differential thermal analyzer and Thermogravimetric analyzer (DTA-TGA)<\/strong><\/h3>\n<p>Thermogravimetric analysis determines the weight change of a material as a function of temperature. In differential thermal analysis, the temperature difference between a reactive sample and a non-reactive reference is determined as a function of time\/temperature, providing helpful information about the temperatures, thermodynamics, and kinetics of reactions. In a combined DTA-TGA system, thermal and mass change effects are measured concurrently on the same sample (DTA, TG, DTG). Weight changes &amp; enthalpy changes of materials corresponding to the transitions and reactions are monitored as a function of temperature (or time) under a controlled atmosphere. In addition to thermal stability, compositional analysis of the materials can also be performed with this equipment. It can differentiate endothermic and exothermic events, which are not associated with a weight change (e.g., melting and curing) from those involving weight changes (e.g., degradation). Filler content, char residue content, moisture content, etc. can also be determined using this instrument.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/DTA-TGA.png\" alt=\"Simultaneous Differential thermal analyzer and Thermogravimetric analyzer (DTA-TGA)\" width=\"211\" height=\"171\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: SDT Q 600 (TA Instruments, USA)\n<h4><strong>Specifications:<\/strong><\/h4>\nTemperature range: Room temperature to 1500 \u00b0C (Nitrogen atmosphere)\n<h4><strong>Applications:<\/strong><\/h4>\n<p>TGA would help to understand the thermal stability of materials which is a necessary pre-requisite for any material to be used for device development. The technique can be used to estimate the percentage composition of constituents in polymer composites. Ash content, moisture content, and filler content of polymer-based materials could also be obtained by Thermogravimetric analysis.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nThermogravimetric analysis (Up to 600\u00baC)\nThermogravimetric analysis (Up to 1200\u00baC)\nDifferential thermal analysis (Up to 600\u00baC)\nDifferential thermal analysis (Up to 1200\u00baC)\n<h3><strong>9. Texture Analyzer<\/strong><\/h3>\n<p>Texture analyzer is used for mechanical testing of tissues, food, cosmetics, pharmaceuticals, adhesives, and other consumer products in compression or tension mode. It assesses textural properties by capturing force, distance, and time data at nearly 500 points per second. Samples are either placed on the base of the texture analyzer or held between two suitable fixtures. In a simple test, the arm of the texture analyzer containing a load cell moves down to penetrate or compress the product and then returns to its initial position. It is capable of performing a wide array of tests.<\/p>\n<h4><strong>Instrument Details:<\/strong><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Texture%20Analyzer.png\" alt=\"Texture Analyzer\" width=\"199\" height=\"265\" border=\"0\" \/><\/h4>\nModel and manufacturer: TA. XT Plus (Stable Micro Systems, UK)\n<h4><strong>Specifications:<\/strong><\/h4>\nForce range: \u00b150 Kg\nForce resolution: 0.1 gm\nSpeed range: 0.01-20 mm\/sec\n<h4><strong>Applications:<\/strong><\/h4>\n<p>Textural analyzers can be used for mechanical testing (tensile, compression, and flexural) of small devices and biological samples that cannot be analyzed by conventional mechanical testing systems like UTM. In addition to mechanical testing of films\/tissues (Compression and tension), the texture analyzer can perform fracturability, muco-adhesiveness, tear strength, burst resistance, peel strength, conformability, and burst strength of films, fabrics, wound dressings, and polymers. It is capable of performing the characterization of gel samples by gel strength (bloom strength for Gelatin), injectability, and syringeability of gels. It could also be used for studying the compression characteristics of devices like stents, vascular grafts, and intraocular lenses.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nTensile Strength (ASTM D882) of tissues or soft devices\nCompressive Strength of tissues or soft devices\nCompression Characteristics of Contact Lenses\nMucoadhesion test\nAdhesiveness of Patches\nPeeling Force of Medical Films\/Adhesive Materials\nGel Consistency\/Strength\nBloom Strength of Gelatin (ISO 9665)\nInjectability of Gels and Solutions\nSyringeability of Gels and Solutions\nCrush Resistance of Vascular Grafts\nFlexural or Three Point Bend Test\nConformability of primary wound dressings\n<h3><strong>10. Confocal Raman Microscope<\/strong><\/h3>\n<p>The Raman Effect is based on the scattering of light when interacting with the chemical bonds of a compound. The interaction of photons with chemical bonds causes specific energy shifts in the backscattered light which could be analyzed to get the Raman spectrum of the compound. The Raman spectrum is unique for each chemical composition and can provide qualitative and quantitative information about the material. Confocal Raman microscopy is a high-resolution imaging technique widely used to characterize materials and specimens in terms of their chemical composition without any labeling. The following information can be obtained using this equipment: Determination of the chemical structure of molecules by Micro Raman spectroscopy, Confocal Raman imaging (hyperspectral image generation with details of complete Raman spectrum at pixel level), Chemical mapping of the distribution of components in a mixture by Raman imaging, depth profiling, drug in excipients\/tablets, drug-eluting stent coatings, live-cell imaging, bacterial imaging, etc.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Confocal%20Raman.png\" alt=\"Confocal Raman Microscope\" width=\"200\" height=\"267\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: Alpha300 RA (WITec GmbH, Germany)\n<h4><strong>Specifications:<\/strong><\/h4>\nExcitation Laser 1. Frequency-doubled Nd: YAG dye laser [max power output 40 mW at 532 nm].\nExcitation Laser 2. High-Power Single Frequency Diode Laser [max power output 300 mW at 785 nm].\n<h4><strong>Applications:<\/strong><\/h4>\n<p>Micro Raman spectroscopy can be used as a tool for material identification complementary to FTIR spectroscopy. The advantage of Raman over FTIR is that it can be used for the analysis of materials having moisture content. Hence this technique is suitable for the analysis of biomolecules, live cells, tissues, etc. It is suitable for the analysis of all kinds of materials encompassing polymers, organic molecules, inorganic materials, ceramics, metals, and alloys. Raman chemical mapping can be effectively used to distinguish materials of different chemical origins, cells with distinct features, adsorption or inclusion of certain chemical moieties on or in the cells, imaging bacterial colonies, etc. It can be used for analyzing forensic samples for detecting forgery, fingerprint analysis, gunpowder residue analysis, etc. It can be used in the pharmaceutical sector for analyzing the distribution of drugs in combinations, coating of drugs in combinatorial devices, drug emulsions, etc.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nMicro Raman spectroscopic analysis\nChemical mapping using confocal Raman microscope (Raman imaging)\n<h3><strong>11. Luminescent Image Analyzer<\/strong><\/h3>\n<p>By using a wide variety of light sources and optical filters, fluorescence and chemiluminescence of the samples, especially biological samples, can be quantified and imaged. It has a multipurpose CCD camera system for sensitive and quantitative imaging of membranes, gels, colony counting, etc.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Luminescent%20Image.png\" alt=\"Luminescent Image Analyzer\" width=\"208\" height=\"278\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: LAS 4000 (Fuji Film, Japan)\n<h4><strong>Specifications:<\/strong><\/h4>\nFilters available &#8211; 460nm (blue), 520nm (green), 630nm (red), 710nm (IR), 312 &amp; 365 nm (UV), and white light.\n<h4><strong>Applications:<\/strong><\/h4>\n<p>The luminescent image analyzer is suitable for the imaging of samples and small animals with suitable light sources covering IR, Visible light, and UV. It can also image samples of Agarose and polyacrylamide gels, Western blot imaging, thin layer chromatography plates, etc.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nLuminescent image analysis\n<h3><strong>12. Rapid Visco Analyzer<\/strong><\/h3>\n<p>Rapid Visco Analyzer is a viscometer with ramped temperature and variable shear capability optimized for testing the viscous properties of different types of samples. However, it is essential to highlight its versatility due to its capacity to analyze the viscosity in heating-cooling cycles. It can determine the solution viscosity and the viscous properties of biopolymers such as starch, alginate, chitosan, hydrocolloids, proteins, etc.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Rapid%20Visco.png\" alt=\"Rapid Visco Analyzer\" width=\"188\" height=\"251\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: RVA Starch Master 2 (Newport Scientific, Australia).\n<h4><strong>Specifications:<\/strong><\/h4>\nViscosity range: 40 &#8211; 14000cP at 80 rpm and 20 &#8211; 8000 cP at 160 rpm\nViscosity accuracy: \u00b13%\nSpeed range: 20 &#8211; 1000 rpm\nTemperature range: ambient to 99 \u00baC\n<h4><strong>Applications:<\/strong><\/h4>\n<p>This equipment is useful in estimating the solution viscosities of biopolymer solutions and their variation in response to temperature. In addition to viscosity, the equipment can be used for analyzing the pasting strength of starch.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nSolution Viscosity analysis\n<h3><strong>13. Force Tensiometer<\/strong><\/h3>\n<p>The Force tensiometer is used for the surface property analysis of liquids and solids. As the testing is carried out as force measurements, the dynamic changes of the surface properties can be analyzed accurately by this equipment. Its high sensitivity enables the accurate estimation of surface and interface properties. Apart from the surface and interfacial tensions, it could be used to estimate critical micelle concentration, the dynamic contact angle of the materials, powder wettability, and surface-free energy calculations.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Force%20Tensiometer.png\" alt=\"Force Tensiometer\" width=\"181\" height=\"372\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: Sigma 701 (KSV Instruments Ltd, Finland).\n<h4><strong>Specifications:<\/strong><\/h4>\nMax. Balance Load: up to 5g\nWeighing Resolution: 0.001mg\nMeasuring range: up to 1000 mN\/m\nResolution: 0.001mN\nM Stage Speed: 0.01-500 mm\/min\nStage Position Resolution: 0.015 \u03bcm\n<h4><strong>Applications:<\/strong><\/h4>\n<p>A force tensiometer is a package for the surface analysis of liquids and solids. It can be used for the analysis of surface tension\/ interfacial tension of liquids, critical micelle concentration, and the dynamic contact angle of solids by Du Nouy Ring and Wilhelmy methods. It could be used for the powder wettability analysis to estimate the contact angles of powders in various liquids by the Washburn approach. The system is capable of the surface free energy calculations of solids by analyzing contact angles in different solvents.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nSurface\/interfacial tension of liquids\nDynamic contact angle measurement\nPowder wettability studies\nSurface free energy calculation of solids\n<h3><strong>14. Universal Testing Machine (UTM) Equipped with BioPuls Bath<\/strong><\/h3>\n<p>Universal testing machine is used for determining the mechanical properties of materials. The accessory, BioPuls temperature-controlled bath, enables the system to perform mechanical testing at ambient and simulated physiological conditions. The instrument can analyze a wide variety of samples, such as Polymer films, fabrics, gloves, polymer or ceramic composites, dental materials, etc., in tension and compression modes.<img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/UTM.png\" alt=\"Universal Testing Machine (UTM) Equipped with BioPuls Bath\" width=\"194\" height=\"531\" border=\"0\" \/><\/p>\n<h4><strong>Instrument Details:<\/strong><\/h4>\nModel and manufacturer: Instron 3345 with BioPuls temperature-controlled bath (Instron, USA)\n<h4><strong>Specifications:<\/strong><\/h4>\nSingle Column Materials Testing System\nLoad cell Capacity &#8211; 500 N and 5 kN\nBioPuls temperature-controlled bath for simulating physiological conditions.\n<h4><strong>Applications:<\/strong><\/h4>\n<p>Instron 3345 with BioPuls temperature-controlled bath is capable of the mechanical testing of samples in ambient and physiological conditions. In addition to tensile and compression analysis of materials, the equipment can be used for estimating the tear strength, conformability, and burst resistance of materials.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nTensile analysis of materials at ambient conditions\nTensile analysis of materials at physiological conditions\nCompression analysis of materials at ambient conditions\nTensile analysis of PPE (Dry)\nTensile analysis of PPE (Wet)\nTensile strength and elongation of medical gloves (Before aging)\nTensile strength and elongation of medical gloves (After aging)\nTear strength of PPE by trapezoidal method\nTear strength of fabrics by single rip procedure\n<h3><strong>15. Payne Permeability Cup for Water Vapor Transmission Rate<\/strong><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Payne%20Permeability%20Cup%20for%20Water%20Vapor%20Transmission%20Rate.png\" alt=\"Payne Permeability Cup for Water Vapor Transmission Rate\" width=\"218\" height=\"223\" border=\"0\" \/><\/h3>\n<p>Water vapor transmission rate (WVTR) is one of the inevitable tests to qualify textile materials, personal protective equipment, and wound dressing materials. CAF employs a Payne permeability cup (Make: Elcometer; Area: 30 cm2; volume capacity: 50 ml.) to estimate the water vapor transmission rate of films as per international standards (Gravimetric method).<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nWater vapor transmission rate of primary wound dressings\nWater vapor transmission rate of polymer films and flexible packaging\nWater vapor transmission rate of PPE\n<h3><strong>16. Synthetic Blood Penetration Test System<\/strong><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Synthetic%20Blood%20Penetration%20Test%20System.png\" alt=\"Synthetic Blood Penetration Test System\" width=\"266\" height=\"165\" border=\"0\" \/><\/h3>\n<p>The synthetic blood penetration test is one of the inevitable tests to qualify the medical textile materials including personal protective equipment (PPE), coveralls, drapes, gowns, etc. This test qualifies the medical textile to be safe to guard the user from undesirable contact with patient blood. CAF employs a method as per ASTM F1670 to check the resistance of medical textiles to prevent the penetration of synthetic blood.<\/p>\n<h3><strong>17. Portable handheld X-Ray Fluorescence Analyzer<\/strong><\/h3>\n<p>Handheld X-ray fluorescence (XRF) analyzer is a powerful tool to analyze the elemental composition of samples in a wide range of applications. This is a fast, accurate, and non-destructive testing equipment that utilizes energy-dispersive X-ray fluorescence for the detection and analysis of elements ranging from Mg to U without any sample preparation. Here the X-ray produced by the Rh anode source is used to irradiate the sample which results in the emission of X-rays with discrete energies unique for different elements present in the sample. Analysis of fluorescent X-rays will help to identify and quantify the elements present.<\/p>\n<h4><strong>Instrument Details:<\/strong><img loading=\"lazy\" decoding=\"async\" src=\"\/wp-content\/uploads\/BMT-wing\/Portable%20handheld%20X-Ray%20Fluorescence%20Analyzer.png\" alt=\"Portable handheld X-Ray Fluorescence Analyzer\" width=\"179\" height=\"262\" border=\"0\" \/><\/h4>\nModel: X200, Make: Sci Aps USA (Quantum equipment)\n<h4><strong>Specifications:<\/strong><\/h4>\nExcitation source: 40\/50 kV, 100 \u00b5A Rh anode\nDetector: Silicon drift SDD detector\nResolution: \u02c2135 eV\nElemental range: Mg to U\n<h4><strong>Applications:<\/strong><\/h4>\n<p>XRF analysis would help in the elemental analysis of materials. The relative composition of elements can be used to identify the alloy grades as well. The inbuilt alloy library could be useful for the identification of over 300 grades of alloys. In addition to the alloy analysis, the equipment has modules for RoHS compliance testing, precious metal analysis, and coating thickness measurements.<\/p>\n<h4><strong>Tests offered:<\/strong><\/h4>\nAlloy analysis\nRoHS compliance testing of polymers\n<p><b><\/b><\/p>\n<h4>For further details on tests offered, test request forms, inquiries related to payment, etc., please contact:<\/h4>\n<p><\/p>\nScientist-In-Charge,<br \/>\nCustomer Service Cell,<br \/>\nBiomedical Technology Wing,<br \/>\nSCTIMST, Poojapura,<br \/>\nTrivandrum &#8211; 695012, India.<br \/>\nEmail: csc@sctimst.ac.in<br \/>\nTel.: +91-471-2520307\/2520309\n<h2><strong>Staff<\/strong><\/h2>\n\n\n","protected":false},"excerpt":{"rendered":"<div class=\"entry-summary\">\n<div class=\"entry-summary\">\nThe physicochemical characterization of biomaterials is a critical step in understanding their suitability for specific applications, ensuring their&hellip;\n<\/div>\n<div class=\"link-more\"><a href=\"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &ldquo;Central\u00a0Analytical\u00a0Facility&rdquo;<\/span>&hellip;<\/a><\/div>\n<\/div>\n<div class=\"link-more\"><a href=\"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &ldquo;Central\u00a0Analytical\u00a0Facility&rdquo;<\/span>&hellip;<\/a><\/div>","protected":false},"author":1,"featured_media":0,"parent":2311,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"templates\/with-sidebar.php","meta":{"footnotes":""},"class_list":["post-2315","page","type-page","status-publish","hentry","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/\" \/>\n<meta property=\"og:locale\" content=\"hi_IN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum\" \/>\n<meta property=\"og:description\" content=\"The physicochemical characterization of biomaterials is a critical step in understanding their suitability for specific applications, ensuring their&hellip; Continue reading &ldquo;Central\u00a0Analytical\u00a0Facility&rdquo;&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/\" \/>\n<meta property=\"og:site_name\" content=\"SCTIMST\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-19T09:27:06+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0905\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u092a\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u092e\u092f\" \/>\n\t<meta name=\"twitter:data1\" content=\"22 \u092e\u093f\u0928\u091f\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/\",\"url\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/\",\"name\":\"Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/new1.sctimst.ac.in\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/FTIR1-300x218.png\",\"datePublished\":\"2024-12-16T08:13:02+00:00\",\"dateModified\":\"2025-09-19T09:27:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/#breadcrumb\"},\"inLanguage\":\"hi-IN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"hi-IN\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/#primaryimage\",\"url\":\"http:\\\/\\\/new1.sctimst.ac.in\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/FTIR1-300x218.png\",\"contentUrl\":\"http:\\\/\\\/new1.sctimst.ac.in\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/FTIR1-300x218.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/central-analytical-facility\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"About SCTIMST\",\"item\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Departments and Divisions\",\"item\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Departments and Divisions BMT Wing\",\"item\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/about-sctimst\\\/departments-divisions\\\/biomedical-technology-wing\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Central\u00a0Analytical\u00a0Facility\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#website\",\"url\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/\",\"name\":\"SCTIMST\",\"description\":\"Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum\",\"publisher\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"hi-IN\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#organization\",\"name\":\"SCTIMST\",\"url\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"hi-IN\",\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/cropped-logo_black_300-1.png\",\"contentUrl\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/cropped-logo_black_300-1.png\",\"width\":300,\"height\":351,\"caption\":\"SCTIMST\"},\"image\":{\"@id\":\"https:\\\/\\\/new1.sctimst.ac.in\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/","og_locale":"hi_IN","og_type":"article","og_title":"Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum","og_description":"The physicochemical characterization of biomaterials is a critical step in understanding their suitability for specific applications, ensuring their&hellip; Continue reading &ldquo;Central\u00a0Analytical\u00a0Facility&rdquo;&hellip;","og_url":"https:\/\/new1.sctimst.ac.in\/hi\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/","og_site_name":"SCTIMST","article_modified_time":"2025-09-19T09:27:06+00:00","og_image":[{"url":"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"\u0905\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u092a\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u092e\u092f":"22 \u092e\u093f\u0928\u091f"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/","url":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/","name":"Central\u00a0Analytical\u00a0Facility - Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum","isPartOf":{"@id":"https:\/\/new1.sctimst.ac.in\/#website"},"primaryImageOfPage":{"@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/#primaryimage"},"image":{"@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/#primaryimage"},"thumbnailUrl":"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png","datePublished":"2024-12-16T08:13:02+00:00","dateModified":"2025-09-19T09:27:06+00:00","breadcrumb":{"@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/#breadcrumb"},"inLanguage":"hi-IN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/"]}]},{"@type":"ImageObject","inLanguage":"hi-IN","@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/#primaryimage","url":"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png","contentUrl":"http:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/FTIR1-300x218.png"},{"@type":"BreadcrumbList","@id":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/central-analytical-facility\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/new1.sctimst.ac.in\/"},{"@type":"ListItem","position":2,"name":"About SCTIMST","item":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/"},{"@type":"ListItem","position":3,"name":"Departments and Divisions","item":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/"},{"@type":"ListItem","position":4,"name":"Departments and Divisions BMT Wing","item":"https:\/\/new1.sctimst.ac.in\/about-sctimst\/departments-divisions\/biomedical-technology-wing\/"},{"@type":"ListItem","position":5,"name":"Central\u00a0Analytical\u00a0Facility"}]},{"@type":"WebSite","@id":"https:\/\/new1.sctimst.ac.in\/#website","url":"https:\/\/new1.sctimst.ac.in\/","name":"\u090f\u0938\u0938\u0940\u091f\u0940\u0906\u0908\u090f\u092e\u090f\u0938","description":"Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum","publisher":{"@id":"https:\/\/new1.sctimst.ac.in\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/new1.sctimst.ac.in\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hi-IN"},{"@type":"Organization","@id":"https:\/\/new1.sctimst.ac.in\/#organization","name":"\u090f\u0938\u0938\u0940\u091f\u0940\u0906\u0908\u090f\u092e\u090f\u0938","url":"https:\/\/new1.sctimst.ac.in\/","logo":{"@type":"ImageObject","inLanguage":"hi-IN","@id":"https:\/\/new1.sctimst.ac.in\/#\/schema\/logo\/image\/","url":"https:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/cropped-logo_black_300-1.png","contentUrl":"https:\/\/new1.sctimst.ac.in\/wp-content\/uploads\/2024\/12\/cropped-logo_black_300-1.png","width":300,"height":351,"caption":"SCTIMST"},"image":{"@id":"https:\/\/new1.sctimst.ac.in\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/pages\/2315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/comments?post=2315"}],"version-history":[{"count":24,"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/pages\/2315\/revisions"}],"predecessor-version":[{"id":6753,"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/pages\/2315\/revisions\/6753"}],"up":[{"embeddable":true,"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/pages\/2311"}],"wp:attachment":[{"href":"https:\/\/new1.sctimst.ac.in\/hi\/wp-json\/wp\/v2\/media?parent=2315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}